Model |
MS-35-5 |
MS-35-12 |
MS-35-15 |
MS-35-24 | |
|
Output |
DC voltage |
5V |
12V |
15V |
24V |
|
Voltage tolerance |
2% |
1% |
1% |
1% | |
|
Rated current |
7A |
3A |
2.4A |
1.5A | |
|
Current range |
0~7A |
0~3A |
0~2.4A |
0~1.5A | |
|
Rated power |
25W |
36W |
36W |
36W | |
|
Ripple&noise |
80mvp-p |
120mvp-p |
120mvp-p |
120mvp-p | |
|
DCvoltage ADJ.range |
-9%~+10% |
10% |
10% |
10% | |
|
Input |
Voltage range |
170~264VAC, 235~373VDC | |||
|
frequency |
47~63HZ | ||||
|
AC current |
0.45A/230VAC | ||||
|
efficiency |
76% |
78% |
78% |
80% | |
|
Inrush current |
Cold start current 30A/230VAC | ||||
|
Leakage current |
< 1mA/240VAC | ||||
|
Protection |
overload |
Rated output power115%~135% start over load protection | |||
|
protection type: hiccup mode, auto-recovery after fault condition is removed | |||||
|
over voltage |
Rated output power145%~170% | ||||
|
protection type: hiccup mode, auto-recovery after fault condition is removed | |||||
|
over temp |
When temperature of transistor inner node is over 150,Start over temp protection | ||||
|
protection type: hiccup mode, auto-recovery after temperature become normal | |||||
|
Environment |
Working temp,humidity |
-10C~+60C, 20%~90%RH | |||
|
Storagetemp,humidity |
-20C~+85C, 0%~95%RH non-condensing | ||||
|
Withstand vibration |
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes | ||||
|
Safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
|
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC | ||||
|
Fitstandard |
Safety standard |
Fit UL1012 | |||
|
EMC standard |
EN55022, CLASSA | ||||
|
Others |
Dimension |
84*58*38mm (L*W*H) | |||
|
Weight/packing |
0.17kg/80pcs/14.5kg/0.024m³/0.87CUFT | ||||
|
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||